The University of Arizona
http://www.genome.arizona.edu
5 x 5 Grid Clones - AGI > Research > Protocols - - Publisher
AGI > Research > Protocols > 5 x 5 Grid Clones

5 x 5 Grid Clones

How to identify an address:
The membrane is divided into 6 fields (diagram provided). Each field contains 384 squares. The 384 squares represent the row and column identification of the BAC. Within each square there are 24 positions (middle is empty) where 12 clones are spotted in duplicate (SEE 5X5 diagram). The pattern of the spotted clones will generate the plate address of the BAC. To identify your clone, please follow the directions below.

The most complicated part about identifying a clone address is that consecutive plates are not spotted into each field. The 384 well plates are spotted onto the membrane with plates 1-6 spotted into fields 1-6 respectively (duplication pattern 1, see diagram). Since there is a total of 6 fields on the membrane, the cycle will continue with the next 6 consecutive plates (plates 7 through 12) again being spotted into fields 1 through 6 respectively, but in a different duplication pattern (duplication pattern 2, see diagram). This gridding cycle will continue until all the plates have been spotted.

1. The library name and filter number is used to orient the membrane. Place the membrane with the label facing up and on the right-hand side as shown in the diagram. (The colonies are on the same side of the filter as the label)
2. Identify the field number of the hybridizing colonies. The spacing of colonies is slightly wider between the fields.
3. Identify the well location (I have included a grid to help locate well positions) and identify the well position (e.g. L18)
4. Identify the plate number. This is accomplished by determining the orientation of the duplicate spots (duplication pattern in the diagram) and referring to the table inside each field in the figure.
5. Libraries which have more than one filter (72 plates) will also need to decode the plate number based on the filter. Plates 1-72 are spotted on filterA, 73-144 on filterB, etc. Identify the plate number and well location as described above and record the filter letter. Go to the conversion table and read down the column corresponding to the filter letter and read across the plate number identified from the filter. The intersection is the actual plate number of the clone.

Example: If you have horizontal spots, they could either be duplication position 4 or 5 or 12 (from the duplication pattern). They are distinguished by the closeness of the spots and position in the pattern. Assume it is position 4 in field 3. Read down the table in field 3 of the diagram to pos4 and read the plate number as 21. If you are reading filterB, identify the library plate number from row 21 and the column labeled FilterB of the library filter plate decoder. The library plate number is 93. Once the plate number is determined, identify the well location either by using the supplied grid or counting the rows and columns.

High Density filters: 5 X 5 Pattern in Six Fields ( Powerpoint Slide )

Address Fields for 5 x 5 gridding ( Powerpoint Slide )

Library plate decoder for 5x5 grid filter
  View this article in PDF format Print article

Files linked to this article
File name Published on Hits
Download this file 5x5_plates.xls
Library plate decoder for 5x5 grid filter
2012/1/20 345
Download this file 5x5_grid_pattern_slide2.ppt
Address Fields for 5 x 5 gridding
2012/1/20 333
Download this file 5x5_grid_pattern_slide1.ppt
High Density filters: 5 X 5 Pattern in Six Fields
2012/1/20 326

Go to
Previous 4 x 4 Grid Clones, SIX Fields AGI BAC Filter Manual Next
Sponsors: